The DataPower Gateway must use automated mechanisms to alert security personnel to threats identified by authoritative sources (e.g., CTOs) and in accordance with CJCSM 6510.01B.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-65173WSDP-NM-000131SV-79663r1_ruleCCI-000366medium
Description
By immediately displaying an alarm message, potential security violations can be identified more quickly even when administrators are not logged into the network device. An example of a mechanism to facilitate this would be through the utilization of SNMP traps.
STIGDate
IBM DataPower Network Device Management Security Technical Implementation Guide2017-10-05

Details

Check Text (C-79663r1_chk)

Go to Administration >> Access >> SNMP Settings. Verify the IP address, port, and security settings. Go to the Trap and Notification Targets tab. Verify the remote server/receiver information. If these values have not been set, this is a finding.

Fix Text (F-71113r1_fix)

Go to Administration >> Access >> SNMP Settings. Configure the IP address, port, and security settings. Go to the Trap and Notification Targets tab. Enter the remote server/receiver information.