UCF STIG Viewer Logo

The INSTDATA Control Option is not set to (0).


Overview

Finding ID Version Rule ID IA Controls Severity
V-200 TSS0410 SV-200r2_rule DCCS-1 DCCS-2 Medium
Description
The INSTDATA Control Option controls the value of the 4-byte global data installation data area. This value is passed to the security exit developed at a particular site. The system-wide options control the default settings for determining how the ACP will function when handling requests for access to the operating system environment, ACP, and customer data. The ACP provides the ability to set a number of these fields at the subsystem level. If no setting is found, the system-wide defaults will be used. The improper setting of any of these fields, individually or in combination with another, can compromise the security of the processing environment. In addition, failure to establish standardized settings for the ACP control options introduces the possibility of exposure during migration process or contingency plan activation.
STIG Date
z/OS TSS STIG 2019-12-12

Details

Check Text ( C-453r1_chk )
a) Refer to the following report produced by the TSS Data Collection:

- TSSCMDS.RPT(TSSPRMFL)

Automated Analysis
Refer to the following report produced by the z/OS Data Collection:

- PDI(TSS0410)

b) If the INSTDATA Control Option is set to (0), there is NO FINDING.

c) If the INSTDATA Control Option is set to a value other than (0), this is a FINDING.
Fix Text (F-17093r1_fix)
Evaluate the impact associated with implementation of the control option. Develop a plan of action to set the INSTDATA control option value to (0) and proceed with the change.