Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-206 | TSS0470 | SV-206r2_rule | DCCS-1 DCCS-2 | Medium |
Description |
---|
The MSUSPEND Control Option allows the MSCA ACID to be suspended automatically if the password violation threshold is set via the PTHRESH option and that limit is exceeded. This will prevent a user from making an unlimited number of guess attempts to determine the MSCAs password. The system-wide options control the default settings for determining how the ACP will function when handling requests for access to the operating system environment, ACP, and customer data. The ACP provides the ability to set a number of these fields at the subsystem level. If no setting is found, the system-wide defaults will be used. The improper setting of any of these fields, individually or in combination with another, can compromise the security of the processing environment. In addition, failure to establish standardized settings for the ACP control options introduces the possibility of exposure during migration process or contingency plan activation. |
STIG | Date |
---|---|
z/OS TSS STIG | 2018-04-04 |
Check Text ( C-17932r1_chk ) |
---|
a) Refer to the following report produced by the TSS Data Collection: - TSSCMDS.RPT(STATUS) Automated Analysis Refer to the following report produced by the TSS Data Collection: - PDI(TSS0470) b) If the MSUSPEND Control Option is set to (YES), there is NO FINDING. c) If the MSUSPEND Control Option is NOT set to (YES), this is a FINDING. |
Fix Text (F-17160r1_fix) |
---|
Evaluate the impact associated with implementation of the control option. Develop a plan of action to set the MSUSPEND control option to (YES) and proceed with the change. |