The ADMINBY Control Option is not set to ADMINBY.


Overview

Finding ID Version Rule ID IA Controls Severity
V-70 TSS0249 SV-70r2_rule DCCS-1 DCCS-2 Medium
Description
The ADMINBY Control Option enables administrative information to be recorded for facilities added and resources permitted. The system-wide options control the default settings for determining how the ACP will function when handling requests for access to the operating system environment, ACP, and customer data. The ACP provides the ability to set a number of these fields at the subsystem level. If no setting is found, the system-wide defaults will be used. The improper setting of any of these fields, individually or in combination with another, can compromise the security of the processing environment. In addition, failure to establish standardized settings for the ACP control options introduces the possibility of exposure during migration process or contingency plan activation.
STIG Date
z/OS TSS STIG 2017-06-26

Details

Check Text ( C-17466r1_chk )
a) Refer to the following report produced by the TSS Data Collection:

- TSSCMDS.RPT(STATUS)

Automated Analysis
Refer to the following report produced by the TSS Data Collection:

- PDI(TSS0249)

b) If the ADMINBY Control Option value is specified, there is NO FINDING.

c) If the ADMINBY Control Option value is not set or set to NOADMBY, this is a FINDING.
Fix Text (F-16718r1_fix)
The IAO will ensure ADMINBY control option is set to Adminby to record who when and where information in the ACID security record for administrative changes.
Evaluate the impact associated with implementation of the control option. Develop a plan of action to implement the control option setting ADMINBY and proceed with the change.