The SYSOUT Control Option is not set to (x,LOCAL). **Note: 'x' represents a site defined JES SYSOUT class


Overview

Finding ID Version Rule ID IA Controls Severity
V-219 TSS0620 SV-219r2_rule DCCS-1 DCCS-2 Low
Description
The SYSOUT Control Option spins off a TSS diagnostic log, and specifies the SYSOUT class and destination for the log. The system-wide options control the default settings for determining how the ACP will function when handling requests for access to the operating system environment, ACP, and customer data. The ACP provides the ability to set a number of these fields at the subsystem level. If no setting is found, the system-wide defaults will be used. The improper setting of any of these fields, individually or in combination with another, can compromise the security of the processing environment. In addition, failure to establish standardized settings for the ACP control options introduces the possibility of exposure during migration process or contingency plan activation.
STIG Date
z/OS TSS STIG 2016-12-21

Details

Check Text ( C-497r1_chk )
**NOTE** Replace "x" with JES SYSOUT class - at sites discretion.

a) Refer to the following report produced by the TSS Data Collection:

- TSSCMDS.RPT(STATUS)

Automated Analysis

Refer to the following report produced by the TSS Data Collection:

- PDI(TSS0620)

b) If the SYSOUT Control Option values are not set to SYSOUT(x,LOCAL), there is NO FINDING..

c) If the SYSOUT Control Option values is not set to SYSOUT(x,LOCAL), this is a FINDING.
Fix Text (F-17620r1_fix)
**NOTE** Replace "x" with JES SYSOUT class - at sites discretion.
Evaluate the impact associated with implementation of the control option. Develop a plan of action to implement the control option setting to SYSOUT(x,LOCAL), and proceed with the change.