The Facility Control Option does not specify the sub option of MODE=FAIL.


Overview

Finding ID Version Rule ID IA Controls Severity
V-15098 TSS0385 SV-15870r2_rule DCCS-1 DCCS-2 High
Description
The system-wide options control the default settings for determining how the ACP will function when handling requests for access to the operating system environment, ACP, and customer data. The ACP provides the ability to set a number of these fields at the subsystem level. If no setting is found, the system-wide defaults will be used. The improper setting of any of these fields, individually or in combination with another, can compromise the security of the processing environment. In addition, failure to establish standardized settings for the ACP control options or sub options introduces the possibility of exposure during migration process or contingency plan activation.
STIG Date
z/OS TSS STIG 2015-03-27

Details

Check Text ( C-17904r1_chk )
a) Refer to the following report produced by the TSS Data Collection:

- TSSCMDS.RPT(FACALL)

Automated Analysis
Refer to the following report produced by the TSS Data Collection:

- PDI(TSS0385)

b) If the FACILTY Control Option specifies the sub option of MODE=FAIL there is NO FINDING.

c) If the FACILTY Control Option does not specifies the sub option of MODE=FAIL , this is a FINDING.
Fix Text (F-17068r1_fix)