IBM Tivoli Asset Discovery for zOS (TADz) Started task(s) must be properly defined to the STARTED resource class for RACF.


Overview

Finding ID Version Rule ID IA Controls Severity
V-224540 ZTADR032 SV-224540r520909_rule Medium
Description
Access to product resources should be restricted to only those individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of product resources could potentially compromise the operating system, ACP, and customer data.
STIG Date
z/OS TADz for RACF Security Technical Implementation Guide 2022-10-07

Details

Check Text ( C-26223r520907_chk )
Refer to the following report produced by the RACF Data Collection:

- DSMON.RPT(RACSPT)

Automated Analysis
Refer to the following report produced by the RACF Data Collection:

- PDI(ZTAD0032)

Verify that the IBM Tivoli Asset Discovery for zOS (TADz) started task(s) is (are) defined to the STARTED resource class profile and/or ICHRIN03 table entry.
Fix Text (F-26211r520908_fix)
The IBM Tivoli Asset Discovery for zOS (TADz) system programmer and the IAO will ensure that a product's started task(s) is (are) properly identified and/or defined to the System ACP.

A unique userid must be assigned for the IBM Tivoli Asset Discovery for zOS (TADz) started task(s) thru a corresponding STARTED class entry.

The following sample set of commands is shown here as a guideline:

rdef started TADZMON.** uacc(none) owner(admin) audit(all(read)) stdata(user(TADZMON) group(stc))

setr racl(started) ref