Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-299 | RACF0770 | SV-299r3_rule | DCCS-1 DCCS-2 | Medium |
Description |
---|
Sensitive Utility Controls can run sensitive system privileges or controls, and potentially can circumvent system and security controls. Failure to properly control access to these resources could result in the compromise of the confidentiality, integrity, and availability of the operating system environment, system services, ACP, and customer data. |
STIG | Date |
---|---|
z/OS RACF STIG | 2018-12-20 |
Check Text ( C-3259r2_chk ) |
---|
Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(RACF0770) Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(RACF0770) Ensure that all Sensitive Utilities resources and/or generic equivalent are properly protected according to the requirements specified in Sensitive Utility Controls table in the z/OS STIG Addendum. If the following guidance is true, this is not a finding. ___ The RACF resource access authorizations restrict access to the appropriate personnel. ___ The RACF resource logging is correctly specified. ___ The RACF resource access authorizations are defined with UACC(NONE) and NOWARNING. |
Fix Text (F-18496r4_fix) |
---|
The IAO will work with the systems programmer to verify that the following are properly specified in the ACP. (Note: The resources, and/or resource prefixes identified below are examples of a possible installation. The actual resource type, resources, and/or resource prefixes are determined when the product is actually installed on a system through the product’s installation guide and can be site specific.) Ensure that all Sensitive Utility Controls resources and/or generic equivalent are properly protected according to the requirements specified in Sensitive Utility Controls table in the z/OS STIG Addendum. Use Sensitive Utility Controls table in the z/OS STIG Addendum. This table lists the resources, access requirements, and logging requirements for Sensitive Utilities, ensures the following guidelines are followed: The RACF resources as designated in the above table are defined with a default access of NONE. The RACF resource access authorizations restrict access to the appropriate personnel as designated in the above table. The RACF resource rules for the resources designated in the above table specify UACC(NONE) and NOWARNING. The following commands are provided as a sample for implementing resource controls: RDEF PROGRAM AHLGTF ADDMEM('SYS1.LINKLIB'//NOPADCHK) - DATA('ADDED PER SRR PDI RACF0770 ') - AUDIT(ALL(READ)) UACC(NONE) OWNER(ADMIN) PERMIT AHLGTF CLASS(PROGRAM) ID(stcgaudt) |