UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Quest NC-Pass Started task will be properly defined to the Started Task Table ACID for Top Secret.


Overview

Finding ID Version Rule ID IA Controls Severity
V-17454 ZNCPT032 SV-40876r1_rule ECCD-1 ECCD-2 Medium
Description
Access to product resources should be restricted to only those individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of product resources could potentially compromise the operating system, ACP, and customer data.
STIG Date
z/OS Quest NC-Pass for TSS STIG 2015-01-15

Details

Check Text ( C-3337r1_chk )
Refer to the following report produced by the TSS Data Collection:

- TSSCMDS.RPT(#STC)

Automated Analysis
Refer to the following report produced by the TSS Data Collection:

- PDI(ZNCP0032)

If the Quest NC-Pass started task(s) is (are) defined in the TSS STC record, this is not a finding.
Fix Text (F-3835r1_fix)
The IAO working with the systems programmer will ensure the Quest NC-Pass Started Task(s) is properly identified and/or defined to the System ACP.

A unique ACID must be assigned for the CA 1 Tape Management started task(s) thru a corresponding STC table entry.

The following commands are provided as a sample for defining Started Task(s):

TSS ADD(STC) PROCNAME(NCPASS) ACID(NCPASS)