UCF STIG Viewer Logo

IBM Tivoli NetView Started task(s) must be properly defined to the Started Task Table ACID for Top Secret.


Overview

Finding ID Version Rule ID IA Controls Severity
V-225585 ZNETT032 SV-225585r472553_rule Medium
Description
Access to product resources should be restricted to only those individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of product resources could potentially compromise the operating system, ACP, and customer data.
STIG Date
z/OS NetView for TSS Security Technical Implementation Guide 2022-10-10

Details

Check Text ( C-27284r472551_chk )
Refer to the following report produced by the TSS Data Collection:

- TSSCMDS.RPT(#STC)

Automated Analysis
Refer to the following report produced by the TSS Data Collection:

- PDI(ZNET0032)

Verify that the IBM Tivoli NetView started task(s) is (are) defined in the TSS STC record.
Fix Text (F-27272r472552_fix)
The IBM Tivoli NetView system programmer and the IAO will ensure that a product's started task(s) is (are) properly identified and/or defined to the System ACP.

A unique ACID must be assigned for the IBM Tivoli NetView started task(s) thru a corresponding STC table entry.

The following sample set of commands is shown here as a guideline:

TSS ADD(STC) PROCNAME(CNMPROC) ACID(CNMPROC)
TSS ADD(STC) PROCNAME(CNMPSSI) ACID(CNMPSSI)