UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Compuware Abend-AID Started task will be properly defined to the Started Task Table for Top Secret.


Overview

Finding ID Version Rule ID IA Controls Severity
V-17454 ZAIDT032 SV-43186r1_rule Medium
Description
Access to product resources should be restricted to only those individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of product resources could potentially compromise the operating system, ACP, and customer data.
STIG Date
z/OS Compuware Abend-AID for TSS STIG 2018-07-06

Details

Check Text ( C-41172r1_chk )
Refer to the following report produced by the TSS Data Collection:

- TSSCMDS.RPT(#STC)

Automated Analysis
Refer to the following report produced by the TSS Data Collection:

- PDI(ZAID0032)

If the Compuware Abend-AID started task(s) is (are) defined in the TSS STC record, this is not a finding.
Fix Text (F-36720r2_fix)
The IAO working with the systems programmer will ensure the Compuware Abend-AID Started Task(s) is properly identified and/or defined to the System ACP.

A unique ACID must be assigned for the Compuware Abend-AID started task(s) thru a corresponding STC table entry.

The following commands are provided as a sample for defining Started Task(s):

TSS ADD(STC) PROCNAME(AAVIEWER) ACID(AAVIEWER)
TSS ADD(STC) PROCNAME(BDCAS) ACID(BDCAS)
TSS ADD(STC) PROCNAME(TDCAS) ACID(TDCAS)