UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Compuware Abend-AID STC data sets must be properly protected.


Overview

Finding ID Version Rule ID IA Controls Severity
V-17067 ZAIDA001 SV-43168r2_rule DCSL-1 ECAR-1 ECAR-2 ECAR-3 ECCD-1 ECCD-2 Medium
Description
Compuware Abend-AID STC data sets have the ability to use privileged functions and/or have access to sensitive data. Failure to properly restrict access to these data sets could result in violating the integrity of the base product which could result in compromising the operating system or sensitive data.
STIG Date
z/OS Compuware Abend-AID for ACF2 STIG 2015-09-25

Details

Check Text ( C-41155r1_chk )
Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(AIDSTC)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZAID0001)

Verify that the accesses to the Compuware Abend-AID STC data sets are properly restricted. If the following guidance is true, this is not a finding.

___ The ACF2 data set rules for the data sets restricts READ access to auditors.

___ The ACF2 data set rules for the data sets restricts WRITE and/or greater access to systems programming personnel.

___ The ACF2 data set rules for the data sets restricts WRITE and/or greater access to the Compuware Abend-AID’s STC(s) and/or batch user(s).
Fix Text (F-241r5_fix)
The IAO will ensure that WRITE and/or greater access to Compuware Abend-AID STC data sets is limited to System Programmers and/or Compuware Abend-AID’s STC(s) and/or batch user(s) only. READ access can be given to auditors.

The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have WRITE and/or greater access and if required that all WRITE and/or greater access is logged. He will identify if any additional groups have WRITE and/or greater access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system.

Data sets to be protected will be:
SYS3.ABENDAID.

The following commands are provided as a sample for implementing data set controls:

$KEY(SYS3)
ABENDAID.- UID() R(A) W(A) A(A) E(A)
ABENDAID.- UID() R(A) W(A) A(A) E(A)
ABENDAID.- UID(ABENDAID STCs) R(A) W(A) A(A) E(A)
ABENDAID.- UID() R(A) E(A)