UCF STIG Viewer Logo

CL/SuperSession is not properly defined to the Facility Matrix Table for Top Secret.


Overview

Finding ID Version Rule ID IA Controls Severity
V-224655 ZCLST036 SV-224655r519784_rule Medium
Description
Improperly defined security controls for the Product could result in the compromise of the network, operating system, and customer data.
STIG Date
z/OS CL/SuperSession for TSS Security Technical Implementation Guide 2022-10-10

Details

Check Text ( C-26338r519782_chk )
a) Refer to the following report produced by the TSS Data Collection:

- TSSCMDS.RPT(FACLIST) - Preferred report containing all control option values in effect including default values
- TSSCMDS.RPT(TSSPRMFL) - Alternate report containing only control option values explicitly coded at TSS startup

b) If KLS is properly defined in the Facility Matrix table, there is NO FINDING:

c) If KLS is improperly defined in the Facility Matrix table, this is a FINDING.
Fix Text (F-26326r519783_fix)
Define the CT/Engine started task name KLS as a Facility to TOP SECRET in the Facility Matrix Table using the following example:

*KLS CL/SUPERSESSION
FACILITY(USERxx=NAME=KLS)
FACILITY(KLS=MODE=FAIL,ACTIVE,SHRPRF)
FACILITY(KLS=PGM=KLV,NOASUBM,NOABEND,NOXDEF)
FACILITY(KLS=ID=xx,MULTIUSER,RES,LUMSG,STMSG,WARNPW,SIGN(M))
FACILITY(KLS=NOINSTDATA,NORNDPW,AUTHINIT,NOPROMPT,NOAUDIT)
FACILITY(KLS=NOTSOC,LOG(INIT,SMF,MSG,SEC9))