CL/SuperSession Started task(s) must be properly defined to the Started Task Table ACID for Top Secret.


Overview

Finding ID Version Rule ID IA Controls Severity
V-224654 ZCLST032 SV-224654r519781_rule Medium
Description
Access to product resources should be restricted to only those individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of product resources could potentially compromise the operating system, ACP, and customer data.
STIG Date
z/OS CL/SuperSession for TSS Security Technical Implementation Guide 2021-06-25

Details

Check Text ( C-26337r519779_chk )
Refer to the following report produced by the TSS Data Collection:

- TSSCMDS.RPT(#STC)

Automated Analysis
Refer to the following report produced by the TSS Data Collection:

- PDI(ZCLS0032)

Verify that the CL/SuperSession started task(s) is (are) defined in the TSS STC record.
Fix Text (F-26325r519780_fix)
The CL/SuperSession system programmer and the IAO will ensure that a product's started task(s) is (are) properly identified and/or defined to the System ACP.

A unique ACID must be assigned for the CL/SuperSession started task(s) thru a corresponding STC table entry.

The following sample set of commands is shown here as a guideline:

TSS ADD(STC) PROCNAME(KLS) ACID(KLS)