UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

CL/SuperSession STC data sets will be properly protected.


Overview

Finding ID Version Rule ID IA Controls Severity
V-17067 ZCLSA001 SV-27093r2_rule DCSL-1 ECAR-1 ECAR-2 ECAR-3 ECCD-1 ECCD-2 Medium
Description
CL/SuperSession STC data sets provide the capability to use privileged functions and/or have access to sensitive data. Failure to properly restrict access to their data sets could result in violating the integrity of the base product which could result in compromising the operating system or sensitive data.
STIG Date
z/OS CL/SuperSession for ACF2 STIG 2015-03-27

Details

Check Text ( C-28010r3_chk )
Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(KLSSTC)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZCLS0001)

Verify that the accesses to the CL/SuperSession STC data sets are properly restricted. If the following guidance is true, this is not a finding.

___ The ACF2 data set access authorizations restrict READ access to auditors and authorized users.

___ The ACF2 data set access authorizations restrict WRITE and/or greater access to systems programming personnel.

___ The ACF2 data set rules for the data sets does not restrict WRITE and/or greater access to the product STC(s) and/or batch job(s).
Fix Text (F-3240r2_fix)
The IAO will ensure that WRITE and/or greater access to CL/SuperSession STC data sets are limited to system programmers and CL/SuperSession STC only. Read access can be given to auditors and authorized users.

The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have WRITE and/or greater access and if required that all WRITE and/or greater access is logged. He will identify if any additional groups have WRITE and/or greater access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system.

(Note: The data sets and/or data set prefixes identified below are examples of a possible installation. The actual data sets and/or prefixes are determined when the product is actually installed on a system through the product’s installation guide and can be site specific.)

Data sets to be protected will be: (data sets identified in the configuration member.)
SYS3.OMEGAMON.RLSNAF
SYS3.OMEGAMON.RLSNAM
SYS3.OMEGAMON.RLSTDB
SYS3.OMEGAMON.RLSVLOG

The following commands are provided as a sample for implementing dataset controls:

$KEY(SYS3)
OMEGAMON.RLSNAF UID(*) R(A) E(A)
OMEGAMON.RLSNAF UID(audtaudt) R(A) E(A)
OMEGAMON.RLSNAF UID(syspaudt) R(A) W(A) A(A) E(A)
OMEGAMON.RLSNAF UID(stc KLS) R(A) W(A) A(A) E(A)
OMEGAMON.RLSNAM UID(*) R(A) E(A)
OMEGAMON.RLSNAM UID(audtaudt) R(A) E(A)
OMEGAMON.RLSNAM UID(syspaudt) R(A) W(A) A(A) E(A)
OMEGAMON.RLSNAM UID(stc KLS) R(A) W(A) A(A) E(A)
OMEGAMON.RLSTDB UID(*) R(A) E(A)
OMEGAMON.RLSTDB UID(audtaudt) R(A) E(A)
OMEGAMON.RLSTDB UID(syspaudt) R(A) W(A) A(A) E(A)
OMEGAMON.RLSTDB UID(stc KLS) R(A) W(A) A(A) E(A)
OMEGAMON.RLSVLOG UID(*) R(A) E(A)
OMEGAMON.RLSVLOG UID(audtaudt) R(A) E(A)
OMEGAMON.RLSVLOG UID(syspaudt) R(A) W(A) A(A) E(A)
OMEGAMON.RLSVLOG UID(stc KLS) R(A) W(A) A(A) E(A)