BMC MAINVIEW for z/OS STC data sets are not properly protected.


Overview

Finding ID Version Rule ID IA Controls Severity
V-17067 ZMVZT001 SV-37724r1_rule DCSL-1 ECAR-1 ECAR-2 ECAR-3 ECCD-1 ECCD-2 Medium
Description
BMC MAINVIEW for z/OS STC data sets have the ability to use privileged functions and/or have access to sensitive data. Failure to properly restrict access to these data sets could result in violating the integrity of the base product which could result in compromising the operating system or sensitive data.
STIG Date
z/OS BMC MAINVIEW for z/OS for TSS STIG 2015-01-16

Details

Check Text ( C-26165r1_chk )
Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(MVZSTC)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZMVZ0001)

Verify that the accesses to the BMC MAINVIEW for z/OS STC data sets are properly restricted.

___ The TSS data set rules for the data sets restricts READ access to auditors and authorized users.

___ The TSS data set rules for the data sets restricts UPDATE and/or ALL access to systems programming personnel.

___ The TSS data set rules for the data sets restricts UPDATE and/or ALL access to the BMC MAINVIEW for z/OS’s STC(s) and/or batch user(s).
Fix Text (F-265r1_fix)
The IAO will ensure that update and allocate access to BMC MAINVIEW for z/OS STC data sets is limited to System Programmers and/or BMC MAINVIEW for z/OS’s STC(s) and/or batch user(s) only. Read access can be given to auditors and authorized users.

The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. He will identify if any additional groups have update and/or alter access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system.

Data sets to be protected will be:
SYS3.BMCVIEW (data sets that are altered by the product’s STCs, this can be more specific)

The following commands are provided as a sample for implementing data set controls:

TSS PERMIT() DSN(SYS3.BMCVIEW) ACCESS(ALL)
TSS PERMIT() DSN(SYS3.BMCVIEW) ACCESS(ALL)
TSS PERMIT(MAINVIEW STCs) DSN(SYS3.BMCVIEW) ACCESS(ALL)
TSS PERMIT() DSN(SYS3.BMCVIEW) ACCESS(R)
TSS PERMIT(authorize user) DSN(SYS3.BMCVIEW) ACCESS(R)