V-17067 | Medium | BMC IOA STC data sets will be properly protected. | BMC IOA STC data sets have the ability to use privileged functions and/or have access to sensitive data. Failure to properly restrict access to these data sets could result in violating the... |
V-17985 | Medium | BMC IOA security exits are not installed or configured properly. | The BMC IOA security exits enable access authorization checking to BMC IOA commands, features, and online functionality. If these exit(s) is (are) not in place, activities by unauthorized users... |
V-21592 | Medium | BMC IOA User data sets will be properly protected. | BMC IOA User data sets, IOA Core and Repository, have the ability to use privileged functions and/or have access to sensitive data. Failure to properly restrict access to these data sets could... |
V-17452 | Medium | BMC IOA Started Task name must be properly identified and defined to the system ACP. | BMC IOA requires a started task that will be restricted to certain resources, datasets and other system functions. By defining the started task as a userid to the system ACP, It allows the ACP to... |
V-18014 | Medium | BMC IOA configuration/parameter values are not specified properly. | BMC IOA configuration/parameters control the security and operational characteristics of products. If these parameter values are improperly specified, security and operational controls may be... |
V-17454 | Medium | BMC IOA Started task(s) must be properly defined to the Started Task Table ACID for Top Secret. | Access to product resources should be restricted to only those individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of... |
V-17947 | Medium | BMC IOA resources will be properly defined and protected. | BMC IOA can run with sensitive system privileges, and potentially can circumvent system controls. Failure to properly control access to product resources could result in the compromise of the... |
V-17469 | Medium | BMC IOA is not properly defined to the Facility Matrix Table for Top Secret. | Improperly defined security controls for BMC IOA could result in the compromise of the network, operating system, and customer data. |
V-16932 | Medium | BMC IOA installation data sets will be properly protected. | BMC IOA installation data sets have the ability to use privileged functions and/or have access to sensitive data. Failure to properly restrict access to these data sets could result in violating... |