BMC IOA Started task(s) must be properly defined to the STARTED resource class for RACF.


Overview

Finding ID Version Rule ID IA Controls Severity
V-17454 ZIOAR032 SV-32181r1_rule Medium
Description
Access to product resources should be restricted to only those individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of product resources could potentially compromise the operating system, ACP, and customer data.
STIG Date
z/OS BMC IOA for RACF STIG 2018-09-20

Details

Check Text ( C-20346r1_chk )
Refer to the following report produced by the RACF Data Collection:

- DSMON.RPT(RACSPT)

Automated Analysis
Refer to the following report produced by the RACF Data Collection:

- PDI(ZIOA0032)

Verify that the BMC IOA started task(s) is (are) defined to the STARTED resource class profile and/or ICHRIN03 table entry.
Fix Text (F-3829r1_fix)
The BMC IOA system programmer and the IAO will ensure that a product's started task(s) is (are) properly identified and/or defined to the System ACP.

A unique userid must be assigned for the BMC IOA started task(s) thru a corresponding STARTED class entry.

The following sample set of commands is shown here as a guideline:

rdef started IOAGATE.** uacc(none) owner(admin) audit(all(read)) stdata(user(IOAGATE) group(stc))