UCF STIG Viewer Logo

BMC CONTROL-O is not properly defined to the Facility Matrix Table for Top Secret.


Overview

Finding ID Version Rule ID IA Controls Severity
V-17469 ZCTOT036 SV-32052r1_rule Medium
Description
Improperly defined security controls for the BMC CONTROL-O could result in the compromise of the network, operating system, and customer data.
STIG Date
z/OS BMC CONTROL-O for TSS STIG 2018-09-20

Details

Check Text ( C-340r1_chk )
Refer to the following report produced by the TSS Data Collection:

- TSSCMDS.RPT(FACLIST) - Preferred report containing all control option values in effect including default values
- TSSCMDS.RPT(TSSPRMFL) - Alternate report containing only control option values explicitly coded at TSS startup

Ensure the BMC CONTROL-O Facility Matrix table is defined as follows:

FAC(USERxx=NAME=CONTROLO,PGM=CTO,ID=nn,ACTIVE,SHRPRF)
FAC(CONTROLO=ASUBM,NOABEND,MULTIUSER,NOXDEF,SIGN(S))
FAC(CONTROLO=RES,LUMSG,STMSG,WARNPW,NORNDPW)
FAC(CONTROLO=NOAUDIT,NOTSOC,MODE=FAIL)
FAC(CONTROLO=LOG(SMF,INIT,MSG,SEC9),UIDACID=8,LOCKTIME=000)
Fix Text (F-424r1_fix)
The BMC CONTROL-O system programmer and the IAO will ensure that the TOP SECRET Facility Matrix Table is proper defined using the following example:

CONTROLO:
FAC(USERxx=NAME=CONTROLO,PGM=CTO,ID=nn,ACTIVE,SHRPRF)
FAC(CONTROLO=ASUBM,NOABEND,MULTIUSER,NOXDEF)
FAC(CONTROLO=LUMSG,STMSG,SIGN(S),WARNPW,NORNDPW)
FAC(CONTROLO=NOAUDIT,RES,NOTSOC,MODE=FAIL)
FAC(CONTROLO=LOG(SMF,INIT,MSG,SEC9),UIDACID=8,LOCKTIME=000)