UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

BMC CONTROL-D is not properly defined to the Facility Matrix Table for Top Secret.


Overview

Finding ID Version Rule ID IA Controls Severity
V-17469 ZCTDT036 SV-32053r1_rule ECCD-1 ECCD-2 Medium
Description
Improperly defined security controls for the BMC CONTROL-D could result in the compromise of the network, operating system, and customer data.
STIG Date
z/OS BMC CONTROL-D for TSS STIG 2015-01-15

Details

Check Text ( C-11659r1_chk )
Refer to the following report produced by the TSS Data Collection:

- TSSCMDS.RPT(FACLIST) - Preferred report containing all control option values in effect including default values
- TSSCMDS.RPT(TSSPRMFL) - Alternate report containing only control option values explicitly coded at TSS startup

Ensure the BMC CONTROL-D Facility Matrix table is defined as follows:

FAC(USERxx=NAME=CONTROLD,PGM=CTD,ID=nn,ACTIVE,SHRPRF)
FAC(CONTROLD=ASUBM,NOABEND,MULTIUSER,NOXDEF,SIGN(S))
FAC(CONTROLD=RES,LUMSG,STMSG,WARNPW,NORNDPW)
FAC(CONTROLD=NOAUDIT,NOTSOC,MODE=FAIL)
FAC(CONTROLD=LOG(SMF,INIT,MSG,SEC9),UIDACID=8,LOCKTIME=000)
Fix Text (F-348r1_fix)
The BMC CONTROL-D system programmer and the IAO will ensure that the TOP SECRET Facility Matrix Table is proper defined using the following example:

CONTROLD:
FAC(USERxx=NAME=CONTROLD,PGM=CTO,ID=nn,ACTIVE,SHRPRF)
FAC(CONTROLD=ASUBM,NOABEND,MULTIUSER,NOXDEF)
FAC(CONTROLD=LUMSG,STMSG,SIGN(S),WARNPW,NORNDPW)
FAC(CONTROLD=NOAUDIT,RES,NOTSOC,MODE=FAIL)
FAC(CONTROLD=LOG(SMF,INIT,MSG,SEC9),UIDACID=8,LOCKTIME=000)