Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-17454 | ZCTDR032 | SV-32155r1_rule | ECCD-1 ECCD-2 | Medium |
Description |
---|
Access to product resources should be restricted to only those individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of product resources could potentially compromise the operating system, ACP, and customer data. |
STIG | Date |
---|---|
z/OS BMC CONTROL-D for RACF STIG | 2015-01-15 |
Check Text ( C-3300r1_chk ) |
---|
Refer to the following report produced by the RACF Data Collection: - DSMON.RPT(RACSPT) Automated Analysis Refer to the following report produced by the RACF Data Collection: - PDI(ZCTD0032) Verify that the BMC CONTROL-D started task(s) is (are) defined to the STARTED resource class profile and/or ICHRIN03 table entry. |
Fix Text (F-338r1_fix) |
---|
The BMC CONTROL-D system programmer and the IAO will ensure that a product's started task(s) is (are) properly identified and/or defined to the System ACP. A unique userid must be assigned for the BMC CONTROL-D started task(s) thru a corresponding STARTED class entry. The following sample set of commands is shown here as a guideline: rdef started CONTROLD.** uacc(none) owner(admin) audit(all(read)) stdata(user(CONTROLD) group(stc)) setr racl(started) ref |