UCF STIG Viewer Logo

The OPTS GSO record value must be set to the values specified.


Overview

Finding ID Version Rule ID IA Controls Severity
V-36899 ACF0375 SV-48660r5_rule Medium
Description
The system-wide options control the default settings for determining how the ACP will function when handling requests for access to the operating system environment, ACP, and customer data. The ACP provides the ability to set a number of these fields at the subsystem level. If no setting is found, the system-wide defaults will be used. The improper setting of any one of these fields, individually or in combination with another, can compromise the security of the processing environment. In addition, failure to establish standardized settings for the ACP control options introduces the possibility of exposure during a migration process or contingency plan activation.
STIG Date
z/OS ACF2 STIG 2019-12-12

Details

Check Text ( C-60249r4_chk )
Refer to the following report produced by the ACF2 Data Collection:

- ACF2CMDS.RPT(ACFGSO)

Automated Analysis requires Additional Analysis.
Refer to the following report produced by the ACF2 Data Collection:

- PDI(ACF0375)

If the GSO OPTS record values conform to the following requirements, this is not a finding.

BLPLOG
NOCMDREC
CONSOLE(NOROLL)
CPUTIME(LOCAL)
DATE(MDY)
NODDB
DFTLID()
DFTSTC()
INFOLIST(none | AUDIT | SECURITY | SECURITY, AUDIT)
JOBCHK
MAXVIO(10)
NOTIFY
RPTSCOPE
SHRDASD
STAMPSMF
STC
TAPEDSN
TEMPDSN
NOUADS
NOVTAMOPEN

Fix Text (F-64871r3_fix)
Ensure that the GSO OPTS value is set to valid options. This will also include the GSO OPTS MODE setting from ACF0370.

Define the global options available to the system.

BLPLOG
NOCMDREC
CONSOLE(NOROLL)
CPUTIME(LOCAL)
DATE(MDY)
NODDB
DFTLID()
DFTSTC()
INFOLIST(none | AUDIT | SECURITY | SECURITY, AUDIT)
JOBCHK
MAXVIO(10)
NOTIFY
RPTSCOPE
SHRDASD
STAMPSMF
STC
TAPEDSN
TEMPDSN
NOUADS
NOVTAMOPEN

Example:

SET C(GSO)
INSERT OPTS BLPLOG NOCMDREC CONSOLE(NOROLL) CPUTIME(LOCAL) DATE(MDY) NODDB DFTLID() DFTSTC() INFOLIST(SECURITY, AUDIT) JOBCHK MAXVIO(10)
MODE(ABORT) NOTIFY RPTSCOPE SHRDASD STAMPSMF STC TAPEDSN TEMPDSN NOUADS NOVTAMOPEN

F ACF2,REFRESH(OPTS)