UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The LOGONIDs specified In GSO MAINT records will have the JOB and MAINT attributes specified In the associated LOGONID record.


Overview

Finding ID Version Rule ID IA Controls Severity
V-2 ACF0680 SV-2r3_rule DCCS-1 DCCS-2 Medium
Description
If there is a LOGONID intended for maintenance purposes that does not have the MAINT and JOB attributes specified, then it cannot function as intended. This could result in the inability to perform critical system maintenance tasks.
STIG Date
z/OS ACF2 STIG 2016-01-04

Details

Check Text ( C-17786r3_chk )
Refer to the following reports produced by the ACF2 Data Collection:

- ACF2CMDS.RPT(ACFGSO)
- ACF2CMDS.RPT(ATTMAINT)

Automated Analysis
Refer to the following report produced by the ACF2 Data Collection Checklist:

- PDI(ACF0680)

For each logonid record associated to the LID entry in all GSO MAINT records specify the following, this is not a finding.

___ The JOB and MAINT attributes are specified.
Fix Text (F-16912r2_fix)
The IAO will ensure that logonids assigned to production maintenance tasks have the JOB and MAINT field settings in addition to the default LID field settings.

Production maintenance tasks manage the backups and restoration of data for the Continuity of Operations Plan (COOP) and media maintenance. Logonids assigned to production maintenance tasks will have the following field settings in addition to the default LID field settings:

JOB
MAINT

Example:

SET LID
CHANGE DFSMSHSM JOB MAINT