There are LOGONIDs associated with started tasks that have the MUSASS requirement but do not have both the MUSASS and NO-SMC specified in corresponding LOGONID records.


Overview

Finding ID Version Rule ID IA Controls Severity
V-162 ACF0610 SV-162r2_rule DCCS-1 DCCS-2 Medium
Description
If the LOGONID does not have the MUSASS attribute specified, there is no individual accountability within the associated address space. If NO-SMC is not specified the potential for VSAM data set corruption exists.
STIG Date
z/OS ACF2 STIG 2016-01-04

Details

Check Text ( C-251r1_chk )
a) Refer to the following reports produced by the ACF2 Data Collection:

- ACF2CMDS.RPT(ATTSTC)
- ACF2CMDS.RPT(ATTMUASS)

Automated Analysis
Refer to the following report produced by the ACF2 Data Collection Checklist:

- PDI(ACF0610)

b) Identify the started tasks that have a Multi-User Single Address Space System (MUSASS) requirement.

c) If every logonid associated with a started task that has the MUSASS requirement has the MUSASS and NO-SMC attributes, there is NO FINDING.

d) If any logonid associated with a started task that has the MUSASS requirement does not have the MUSASS and NO-SMC attributes, this is a FINDING.
Fix Text (F-27334r1_fix)
The IAO will ensure that if the STC is a Multi User Single Address Space System (MUSASS), the STC logonid has the MUSASS and NO-SMC attributes.

If the started task (STC) is a Multi User Single Address Space System (MUSASS), the STC logonid will also have the following attributes:

MUSASS
NO-SMC

Example:

SET LID
INSERT logonid STC MUSASS NO-SMC