UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The LINKLST GSO record value if specified only contains trusted system datasets.


Overview

Finding ID Version Rule ID IA Controls Severity
V-138 ACF0330 SV-138r2_rule DCCS-1 DCCS-2 Medium
Description
The system-wide options control the default settings for determining how the ACP will function when handling requests for access to the operating system environment, ACP, and customer data. The ACP provides the ability to set a number of these fields at the subsystem level. If no setting is found, the system-wide defaults will be used. The improper setting of any one of these fields, individually or in combination with another, can compromise the security of the processing environment. In addition, failure to establish standardized settings for the ACP control options introduces the possibility of exposure during a migration process or contingency plan activation.
STIG Date
z/OS ACF2 STIG 2016-01-04

Details

Check Text ( C-17366r1_chk )
a) Refer to the following report produced by the ACF2 Data Collection:

- ACF2CMDS.RPT(ACFGSO)

Automated Analysis
Refer to the following report produced by the ACF2 Data Collection:

- PDI(ACF0330)

b) If the GSO LINKLST record values conform to the following requirements, there is NO FINDING.

Specifies one or more partitioned data sets considered part of the system link (SYS1.LINKLIB) during data set access validation. Only trusted system data sets will be listed. Application libraries will never be included. Example: LIBRARY(SYS1.LINKLIB SYS2A.FDR.LOADLIB)

c) If there is any deviation from the above requirements in the GSO LINKLST record values, this is a FINDING.
Fix Text (F-16537r1_fix)
The IAO will ensure the LINKLIST GSO value if specified only contains trusted system datasets.

Specifies one or more partitioned data
sets considered part of the system link
(SYS1.LINKLIB) during data set
access validation.

Only trusted system data sets will
be listed. Application
libraries will never be included.

Example:

SET C(GSO)
INSERT LINKLST LIBRARY(SYS1.LINKLIB SYS2A.FDR.LOADLIB)

F ACF2,REFRESH(LINKLST)