UCF STIG Viewer Logo

The number of users granted the special privilege OPERATOR is not justified.


Overview

Finding ID Version Rule ID IA Controls Severity
V-181 ACF0850 SV-181r2_rule DCCS-1 DCCS-2 Medium
Description
Users with this privilege can do anything from canceling jobs to disabling the entire system. This could result in the compromise of the confidentiality, integrity, and availability of the operating system, ACP, or customer data.
STIG Date
z/OS ACF2 STIG 2015-06-24

Details

Check Text ( C-273r1_chk )
a) Refer to the following report produced by the ACF2 Data Collection:

- ACF2CMDS.RPT(ATTOPER)

Automated Analysis
Refer to the following report produced by the ACF2 Data Collection Checklist:

- PDI(ACF0850)

b) If the number of users granted the special privilege OPERATOR is strictly controlled and limited to systems programmer and operations personnel, there is NO FINDING.

c) If the number of users granted the special privilege OPERATOR is not strictly controlled and limited to systems programmer and operations personnel, this is a FINDING.
Fix Text (F-17369r1_fix)
The IAO will ensure that access to the special privilege OPERATOR is kept to a minimum and limited to systems programmer and operations personnel.