UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The system must be configured to store all data in the error report archive.


Overview

Finding ID Version Rule ID IA Controls Severity
V-57465 WINER-000011 SV-71901r1_rule ECSC-1 Medium
Description
The error reporting archive is stored locally on the system and is created after an error report has been sent to the local collector or DOD-wide collector (if defined). Storing all data, including memory contents, adds data that is very helpful in analyzing the errors.
STIG Date
Windows Vista Security Technical Implementation Guide 2016-07-22

Details

Check Text ( None )
None
Fix Text (F-62699r1_fix)
Configure the policy value for Computer Configuration -> Administrative Templates -> Windows Components -> Windows Error Reporting -> Advanced Error Reporting Settings -> "Configure Report Archive" to "Enabled" with "Store All" selected for "Archive behavior:".