UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Windows Server 2019 computer clock synchronization tolerance must be limited to five minutes or less.


Overview

Finding ID Version Rule ID IA Controls Severity
V-93451 WN19-DC-000060 SV-103537r1_rule Medium
Description
This setting determines the maximum time difference (in minutes) that Kerberos will tolerate between the time on a client's clock and the time on a server's clock while still considering the two clocks synchronous. In order to prevent replay attacks, Kerberos uses timestamps as part of its protocol definition. For timestamps to work properly, the clocks of the client and the server need to be in sync as much as possible. Satisfies: SRG-OS-000112-GPOS-00057, SRG-OS-000113-GPOS-00058
STIG Date
Windows Server 2019 Security Technical Implementation Guide 2020-06-15

Details

Check Text ( C-92767r1_chk )
This applies to domain controllers. It is NA for other systems.

Verify the following is configured in the Default Domain Policy:

Open "Group Policy Management".

Navigate to "Group Policy Objects" in the Domain being reviewed (Forest >> Domains >> Domain).

Right-click on the "Default Domain Policy".

Select "Edit".

Navigate to Computer Configuration >> Policies >> Windows Settings >> Security Settings >> Account Policies >> Kerberos Policy.

If the "Maximum tolerance for computer clock synchronization" is greater than "5" minutes, this is a finding.
Fix Text (F-99695r1_fix)
Configure the policy value in the Default Domain Policy for Computer Configuration >> Windows Settings >> Security Settings >> Account Policies >> Kerberos Policy >> "Maximum tolerance for computer clock synchronization" to a maximum of "5" minutes or less.