UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Systems must be maintained at a supported servicing level.


Overview

Finding ID Version Rule ID IA Controls Severity
V-73239 WN16-00-000110 SV-87891r1_rule High
Description
Systems at unsupported servicing levels will not receive security updates for new vulnerabilities, which leave them subject to exploitation. Systems must be maintained at a servicing level supported by the vendor with new security updates.
STIG Date
Windows Server 2016 Security Technical Implementation Guide 2019-12-12

Details

Check Text ( C-73343r1_chk )
Open "Command Prompt".

Enter "winver.exe".

If the "About Windows" dialog box does not display "Microsoft Windows Server Version 1607 (Build 14393.xxx)" or greater, this is a finding.

Preview versions must not be used in a production environment.
Fix Text (F-79683r1_fix)
Update the system to a Version 1607 (Build 14393.xxx) or greater.