Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-57473 | WN12-ER-000015 | SV-71941r1_rule | ECSC-1 | Medium |
Description |
---|
The error reporting queue is stored locally on the system and contains the error reports until they have been manually removed or automatically sent to the local collector or DOD-wide collector (if defined). Once a report has been sent to a collector, it is moved to the report archive. Old reports are deleted as new ones arrive once the maximum limit has been met. |
STIG | Date |
---|---|
Windows Server 2012 / 2012 R2 Member Server Security Technical Implementation Guide | 2015-06-16 |
Check Text ( C-58379r1_chk ) |
---|
If the following registry value does not exist or is not configured as specified, this is a finding: Registry Hive: HKEY_LOCAL_MACHINE Registry Path: \SOFTWARE\Policies\Microsoft\Windows\Windows Error Reporting\ Value Name: MaxQueueCount Type: REG_DWORD Value: 0x00000032 (50) (or greater) |
Fix Text (F-62747r1_fix) |
---|
Configure the policy value for Computer Configuration -> Administrative Templates -> Windows Components -> Windows Error Reporting -> Advanced Error Reporting Settings -> "Configure Report Queue" to "Enabled" with "Maximum number of reports to queue:" set to "50" or greater. |