Command line data must be included in process creation events. (Windows 2012 R2)


Overview

Finding ID Version Rule ID IA Controls Severity
V-43239 WN12-CC-000139 SV-56344r1_rule ECSC-1 Medium
Description
Maintaining an audit trail of system activity logs can help identify configuration errors, troubleshoot service disruptions, and analyze compromises that have occurred, as well as detect attacks. Audit logs are necessary to provide a trail of evidence in case the system or network is compromised. Collecting this data is essential for analyzing the security of information assets and detecting signs of suspicious and unexpected behavior. This setting enables the logging of additional data for process creation events.
STIG Date
Windows Server 2012 / 2012 R2 Domain Controller Security Technical Implementation Guide 2014-06-30

Details

Check Text ( C-49388r1_chk )
This requirement is NA for the initial release of Windows 2012. It is applicable to Windows 2012 R2.

Verify the registry value below. If it does not exist or is not configured as specified, this is a finding.

Registry Hive: HKEY_LOCAL_MACHINE
Registry Path: \SOFTWARE\Microsoft\Windows\CurrentVersion\Policies\System\Audit\

Value Name: ProcessCreationIncludeCmdLine_Enabled

Value Type: REG_DWORD
Value: 1
Fix Text (F-49191r1_fix)
This requirement is NA for the initial release of Windows 2012. It is applicable to Windows 2012 R2.

Configure the policy value for Computer Configuration -> Administrative Templates -> System -> Audit Process Creation -> "Include command line in process creation events" to "Enabled".