Windows Server 2012 / 2012 R2 must employ automated mechanisms to determine the state of system components with regard to flaw remediation using the following frequency: continuously, where HBSS is used; 30 days, for any additional internal network scans not covered by HBSS; and annually, for external scans by Computer Network Defense Service Provider (CNDSP).


Overview

Finding ID Version Rule ID IA Controls Severity
V-36734 WN12-GE-000023 SV-51582r3_rule Medium
Description
Without the use of automated mechanisms to scan for security flaws on a continuous and/or periodic basis, the operating system or other system components may remain vulnerable to the exploits presented by undetected software flaws. The operating system may have an integrated solution incorporating continuous scanning using HBSS and periodic scanning using other tools..
STIG Date
Windows Server 2012/2012 R2 Member Server Security Technical Implementation Guide 2019-09-23

Details

Check Text ( C-94151r1_chk )
Verify DoD approved HBSS software is installed, configured, and properly operating. Ask the operator to document the HBSS software installation and configuration.

If the operator is not able to provide a documented configuration for an installed HBSS or if the HBSS software is not properly configured, maintained, or used, this is a finding.
Fix Text (F-100999r1_fix)
Install a DoD approved HBSS software and ensure it is operating continuously.