UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The computer clock synchronization tolerance must meet minimum standards.


Overview

Finding ID Version Rule ID IA Controls Severity
V-2380 AD.4033_2008_R2 SV-36186r1_rule ECSC-1 Medium
Description
This setting determines the maximum time difference (in minutes) that Kerberos will tolerate between the time on a client's clock and the time on a server's clock while still considering the two clocks synchronous. In order to prevent replay attacks, Kerberos uses timestamps as part of its protocol definition. For timestamps to work properly, the clocks of the client and the server need to be in sync as much as possible.
STIG Date
Windows Server 2008 R2 Domain Controller Security Technical Implementation Guide 2012-09-05

Details

Check Text ( C-472r1_chk )
1. Analyze the system using the Security Configuration and Analysis tool.

2. Expand the Security Configuration and Analysis tree view.

3. Navigate to Account Policies -> Kerberos Policy.

4. If the “Maximum tolerance for computer clock synchronization” is greater than ‘5’ minutes, then this is a finding.
Fix Text (F-5785r1_fix)
Configure the Kerberos policy option Maximum tolerance for computer clock synchronization to a maximum of 5 minutes or less.