The system must be configured to collect multiple error reports of the same event type.


Overview

Finding ID Version Rule ID IA Controls Severity
V-57453 WN08-ER-000005 SV-71729r1_rule ECSC-1 Medium
Description
Multiple error reports of the same error type are useful in diagnosing potential system configuration issues, as well as intrusion activity. This setting controls whether error reporting collects additional, second-level report data even if a CAB file containing data about the event types has already been collected.
STIG Date
Windows 8 / 8.1 Security Technical Implementation Guide 2016-07-22

Details

Check Text ( None )
None
Fix Text (F-62521r1_fix)
Configure the policy value for Computer Configuration -> Administrative Templates -> Windows Components -> Windows Error Reporting -> "Do not throttle additional data" to "Enabled".