Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-4108 | WN08-SO-000049 | SV-48121r2_rule | ECRR-1 | Low |
Description |
---|
Audit records may be lost if the security log becomes full. When the audit log reaches a given percent full, an audit event is written to the security log. An event is recorded as a success audit under the category of System. This option may be especially useful if the audit logs are set to be cleared manually. |
STIG | Date |
---|---|
Windows 8 / 8.1 Security Technical Implementation Guide | 2016-07-22 |
Check Text ( None ) |
---|
None |
Fix Text (F-63891r1_fix) |
---|
If the system is configured to send audit records directly to an audit server, or automatically archive full logs, this is NA. This must be documented with the ISSO. Configure the policy value for Computer Configuration -> Windows Settings -> Security Settings -> Local Policies -> Security Options -> "MSS: (WarningLevel) Percentage threshold for the security event log at which the system will generate a warning" to "90%" or less. |