The system must be configured to allow a local or DOD-wide collector to request additional error reporting diagnostic data to be sent.


Overview

Finding ID Version Rule ID IA Controls Severity
V-15717 WN08-ER-000004 SV-48253r3_rule ECSC-1 Medium
Description
Sending additional error reporting data provides valuable system diagnostic and vulnerability information that would otherwise not be generated nor collected. This setting controls whether additional data in support of error reports can be sent to a local or DOD-wide reporting site.
STIG Date
Windows 8 / 8.1 Security Technical Implementation Guide 2016-07-22

Details

Check Text ( None )
None
Fix Text (F-62507r1_fix)
Configure the policy value for Computer Configuration -> Administrative Templates -> Windows Components -> Windows Error Reporting -> "Do not send additional data" to "Disabled".