UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The system must generate an audit event when the audit log reaches a percentage of full threshold.


Overview

Finding ID Version Rule ID IA Controls Severity
V-4108 WN08-SO-000049 SV-48121r1_rule ECRR-1 Low
Description
When the audit log reaches a given percent full, an audit event is written to the security log. An event is recorded as a success audit under the category of System. This option may be especially useful if the audit logs are set to be cleared manually. A recommended setting would be 90 percent.
STIG Date
Windows 8 / 8.1 Security Technical Implementation Guide 2014-12-13

Details

Check Text ( None )
None
Fix Text (F-41258r1_fix)
Configure the policy value for Computer Configuration -> Windows Settings -> Security Settings -> Local Policies -> Security Options -> "MSS: (WarningLevel) Percentage threshold for the security event log at which the system will generate a warning" to "90" or less.