UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Auditing Access of Global System Objects must be turned off.


Overview

Finding ID Version Rule ID IA Controls Severity
V-14228 WN08-SO-000007 SV-48167r2_rule ECSC-1 Medium
Description
Maintaining an audit trail of system activity logs can help identify configuration errors, troubleshoot service disruptions, and analyze compromises that have occurred, as well as detect attacks. Audit logs are necessary to provide a trail of evidence in case the system or network is compromised. Collecting this data is essential for analyzing the security of information assets and detecting signs of suspicious and unexpected behavior. This setting prevents the system from setting up a default system access control list for certain system objects, which could create a very large number of security events, filling the security log in Windows and making it difficult to identify actual issues.
STIG Date
Windows 8 / 8.1 Security Technical Implementation Guide 2014-04-02

Details

Check Text ( C-44867r3_chk )
Analyze the system using the Security Configuration and Analysis snap-in. (See "Performing Analysis with the Security Configuration and Analysis Snap-in" in the STIG Overview document.)
Expand the Security Configuration and Analysis tree view.
Navigate to Local Policies -> Security Options.

If the value for "Audit: Audit the access of global system objects" is not set to "Disabled", this is a finding.

The policy referenced configures the following registry value:

Registry Hive: HKEY_LOCAL_MACHINE
Registry Path: \System\CurrentControlSet\Control\Lsa

Value Name: AuditBaseObjects

Value Type: REG_DWORD
Value: 0
Fix Text (F-41305r2_fix)
Configure the policy value for Computer Configuration -> Windows Settings -> Security Settings -> Local Policies -> Security Options -> "Audit: Audit the access of global system objects" to "Disabled".