Named pipes that can be accessed anonymously must be configured to contain no values.


Overview

Finding ID Version Rule ID IA Controls Severity
V-3338 WN08-SO-000055 SV-48069r2_rule High
Description
Named pipes that can be accessed anonymously provide the potential for gaining unauthorized system access. Pipes are internal system communications processes. They are identified internally by ID numbers that vary between systems. To make access to these processes easier, these pipes are given names that do not vary between systems. This setting controls which of these pipes anonymous users may access.
STIG Date
Windows 8/8.1 Security Technical Implementation Guide 2017-04-28

Details

Check Text ( None )
None
Fix Text (F-41207r2_fix)
Configure the policy value for Computer Configuration >> Windows Settings >> Security Settings >> Local Policies >> Security Options >> "Network access: Named pipes that can be accessed anonymously" to be defined but containing no entries (blank).