Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
WN08-SO-000049 | WN08-SO-000049 | WN08-SO-000049_rule | Low |
Description |
---|
When the audit log reaches a given percent full, an audit event is written to the security log. An event is recorded as a success audit under the category of System. This option may be especially useful if the audit logs are set to be cleared manually. A recommended setting would be 90 percent. |
STIG | Date |
---|---|
Windows 8 Security Technical Implementation Guide | 2012-11-21 |
Check Text ( C-WN08-SO-000049_chk ) |
---|
Analyze the system using the Security Configuration and Analysis snap-in. (See "Performing Analysis with the Security Configuration and Analysis Snap-in" in the STIG Overview document.) Expand the Security Configuration and Analysis tree view. Navigate to Local Policies -> Security Options. (See "Updating the Windows Security Options File" in the STIG Overview document if MSS settings are not visible in the system's policy tools.) If the value for "MSS: (WarningLevel) Percentage threshold for the security event log at which the system will generate a warning" is not set to "90" or less, this is a finding. The policy referenced configures the following registry value: Registry Hive: HKEY_LOCAL_MACHINE Registry Path: \System\CurrentControlSet\Services\Eventlog\Security\ Value Name: WarningLevel Value Type: REG_DWORD Value: 90 If the system is configured to write to an audit server, or is configured to automatically archive full logs, this must be documented with the IAO. |
Fix Text (F-WN08-SO-000049_fix) |
---|
Configure the policy value for Computer Configuration -> Windows Settings -> Security Settings -> Local Policies -> Security Options -> "MSS: (WarningLevel) Percentage threshold for the security event log at which the system will generate a warning" to "90" or less. |