UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The display must turn off after 20 minutes of inactivity when the system is running on battery.


Overview

Finding ID Version Rule ID IA Controls Severity
WN08-CC-000056 WN08-CC-000056 WN08-CC-000056_rule Low
Description
Turning off an inactive display supports energy saving initiatives. It may also extend availability on systems running on a battery.
STIG Date
Windows 8 Security Technical Implementation Guide 2012-11-21

Details

Check Text ( C-WN08-CC-000056_chk )
If the following registry value does not exist or is not configured as specified, this is a finding:

Registry Hive: HKEY_LOCAL_MACHINE
Subkey: \Software\Policies\Microsoft\Power\PowerSettings\3C0BC021-C8A8-4E07-A973-6B14CBCB2B7E\

Value Name: DCSettingIndex

Type: REG_DWORD
Value: 0x000004b0 (1200) or less
Fix Text (F-WN08-CC-000056_fix)
Configure the policy value for Computer Configuration -> Administrative Templates -> System -> Power Management -> Video and Display Settings -> "Turn Off the Display (On Battery)" to "Enabled" with "1200" seconds or less.