The system will be configured to audit "System -> Security System Extension" failures.


Overview

Finding ID Version Rule ID IA Controls Severity
V-26556 WINAU-000954 SV-36002r1_rule ECAR-2 ECAR-3 Medium
Description
Maintaining an audit trail of system activity logs can help identify configuration errors, troubleshoot service disruptions, and analyze compromises that have occurred as well as detecting attacks. Audit logs are necessary to provide a trail of evidence in case the system or network is compromised. Collecting this data is essential for analyzing the security of information assets and detecting signs of suspicious and unexpected behavior. Security System Extension records events related to extension code being loaded by the security subsystem.
STIG Date
Windows 7 Security Technical Implementation Guide 2014-07-03

Details

Check Text ( None )
None
Fix Text (F-29805r1_fix)
Detailed auditing subcategories are configured in Security Settings -> Advanced Audit Policy Configuration. The summary level settings under Security Settings -> Local Policies -> Audit Policy will not be enforced (see V-14230).

Configure the policy value for Computer Configuration -> Windows Settings -> Security Settings -> Advanced Audit Policy Configuration -> System Audit Policies -> System -> "Audit Security System Extension" with “Failure” selected.