UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The system must be configured to audit Object Access - Handle Manipulation failures.


Overview

Finding ID Version Rule ID IA Controls Severity
V-36669 WINAU-000608 SV-49918r1_rule ECAR-2 ECAR-3 Medium
Description
Maintaining an audit trail of system activity logs can help identify configuration errors, troubleshoot service disruptions, and analyze compromises that have occurred, as well as detect attacks. Audit logs are necessary to provide a trail of evidence in case the system or network is compromised. Collecting this data is essential for analyzing the security of information assets and detecting signs of suspicious and unexpected behavior. Handle Manipulation auditing under Object Access is needed to correctly enable the recording of events related to the access and changing of files and directories. Auditing must also be enabled on the specific objects to be audited or with Global Audit Access Auditing configured on the file system.
STIG Date
Windows 7 Security Technical Implementation Guide 2013-10-01

Details

Check Text ( C-45788r1_chk )
Security Option "Audit: Force audit policy subcategory settings (Windows Vista or later) to override audit policy category settings" must be set to "Enabled" (V-14230) for the detailed auditing subcategories to be effective.

Use the AuditPol tool to review the current Audit Policy configuration.
Open a Command Prompt with elevated privileges ("Run as Administrator").
Enter "AuditPol /get /category:*".

If the system does not audit the following, this is a finding.

Object Access -> Handle Manipulation - Failure
Fix Text (F-43045r2_fix)
Configure the policy value for Computer Configuration -> Windows Settings -> Security Settings -> Advanced Audit Policy Configuration -> System Audit Policies -> Object Access -> "Audit Handle Manipulation" with "Failure" selected.