UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Event Viewer events.asp links are available.


Overview

Finding ID Version Rule ID IA Controls Severity
V-15672 5.214 SV-25152r1_rule ECSC-1 Low
Description
This check verifies that Events.asp hyperlinks in Event Viewer are available.
STIG Date
Windows 7 Security Technical Implementation Guide 2012-08-22

Details

Check Text ( C-15316r1_chk )
If the following registry value doesn’t exist or is not configured as specified, then this is a finding:

Registry Hive: HKEY_LOCAL_MACHINE
Subkey: \Software\Policies\Microsoft\EventViewer\

Value Name: MicrosoftEventVwrDisableLinks

Type: REG_DWORD
Value: 0
Fix Text (F-15539r1_fix)
Configure the policy value for Computer Configuration -> Administrative Templates -> System -> Internet Communication Management -> Internet Communication settings “Turn off Event Viewer “Events.asp” links” to “Disabled”.