Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-3472 | 3.084 | SV-29539r1_rule | Low |
Description |
---|
The Windows Time Service controls time synchronization settings. Time synchronization is essential for authentication and auditing purposes. If the Windows Time Service is used, it should synchronize with a secure, authorized time source. Domain joined systems are automatically configured to synchronize with domain controllers. If an NTP server is configured it should synchronize with a secure, authorized time source. |
STIG | Date |
---|---|
Windows 2008 Member Server Security Technical Implementation Guide | 2016-05-12 |
Check Text ( C-39220r1_chk ) |
---|
Review the following registry values: Registry Hive: HKEY_LOCAL_MACHINE Subkey: \Software\Policies\Microsoft\W32time\Parameters\ Value Name: Type Type: REG_SZ Value: Possible values are NoSync, NTP, NT5DS, AllSync And Value Name: NTPServer Type: REG_SZ Value: "address of the time server" The following would be a finding: "Type" has a value of "NTP" or "Allsync" AND the "NTPServer" value is set to "time.windows.com" or other unauthorized server. The following would not be a finding: The referenced registry values do not exist. "Type" has a value of "NoSync" or "NT5DS". "Type" has a value of "NTP" or "Allsync" AND the "NTPServer" is blank or configured to an authorized time server. For DoD organizations, the US Naval Observatory operates stratum 1 time servers, identified at http://tycho.usno.navy.mil/ntp.html. Time synchronization will occur through a hierarchy of time servers down to the local level. Clients and lower level servers will synchronize with an authorized time server in the hierarchy. Domain joined systems are automatically configured to synchronize with domain controllers and would not be a finding unless this is changed. Automated tools may report this as finding even if enabled and configured correctly as the validity of the time server address needs to be verified. |
Fix Text (F-34317r1_fix) |
---|
If the system needs to be configured to an NTP server, configure the system to point to an authorized time server by setting the policy value for Computer Configuration -> Administrative Templates -> System -> Windows Time Service -> Time Providers “Configure Windows NTP Client” to “Enabled”, and configure the “NtpServer” field to point to an authorized time server. |