Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-16005 | 5.079 | SV-16957r1_rule | ECSC-1 | Low |
Description |
---|
This check verifies that the system is configured to remove the Disconnect option from the Shut Down Windows dialog box on the client. |
STIG | Date |
---|---|
Windows 2008 Member Server Security Technical Implementation Guide | 2013-07-03 |
Check Text ( C-32910r1_chk ) |
---|
If the following registry value doesn’t exist or is not configured as specified, this is a finding: Registry Hive: HKEY_LOCAL_MACHINE Subkey: \Software\Microsoft\Windows\CurrentVersion\Policies\Explorer Value Name: NoDisconnect Type: REG_DWORD Value: 1 |
Fix Text (F-16028r1_fix) |
---|
2008 - Configure the policy value for Computer Configuration -> Administrative Templates -> Windows Components -> Terminal Services -> Terminal Server -> Remote Session Environment “Remove ‘Disconnect’ option from the Shut Down dialog” will be set to “Enabled”. |