UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Simultaneous connections to the Internet or a Windows domain must be limited.


Overview

Finding ID Version Rule ID IA Controls Severity
V-63581 WN10-CC-000055 SV-78071r1_rule Medium
Description
Multiple network connections can provide additional attack vectors to a system and must be limited.
STIG Date
Windows 10 Security Technical Implementation Guide 2016-11-03

Details

Check Text ( C-64331r1_chk )
The default behavior for "Minimize the number of simultaneous connections to the Internet or a Windows Domain" is "Enabled".

If the registry value name below does not exist, this is not a finding.

If it exists and is configured with a value of "1", this is not a finding.

If it exists and is configured with a value of "0", this is a finding.

Registry Hive: HKEY_LOCAL_MACHINE
Registry Path: \SOFTWARE\Policies\Microsoft\Windows\WcmSvc\GroupPolicy\

Value Name: fMinimizeConnections

Value Type: REG_DWORD
Value: 1 (or if the Value Name does not exist)
Fix Text (F-69511r1_fix)
The default behavior for "Minimize the number of simultaneous connections to the Internet or a Windows Domain" is "Enabled".

If this needs to be corrected, configure the policy value for Computer Configuration >> Administrative Templates >> Network >> Windows Connection Manager >> "Minimize the number of simultaneous connections to the Internet or a Windows Domain" to "Enabled".