UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The vCenter VAMI service must enable FIPS mode.


Overview

Finding ID Version Rule ID IA Controls Severity
V-259148 VCLD-80-000042 SV-259148r935348_rule High
Description
Encryption is only as good as the encryption modules used. Unapproved cryptographic module algorithms cannot be verified and cannot be relied on to provide confidentiality or integrity, and DOD data may be compromised due to weak algorithms. FIPS 140-2 is the current standard for validating cryptographic modules. Satisfies: SRG-APP-000179-WSR-000111, SRG-APP-000014-WSR-000006, SRG-APP-000416-WSR-000118, SRG-APP-000439-WSR-000188
STIG Date
VMware vSphere 8.0 vCenter Appliance Management Interface (VAMI) Security Technical Implementation Guide 2023-10-29

Details

Check Text ( C-62888r935346_chk )
At the command prompt, run the following command:

# /opt/vmware/sbin/vami-lighttpd -p -f /opt/vmware/etc/lighttpd/lighttpd.conf 2>/dev/null|grep "server.fips-mode"

Expected result:

server.fips-mode = "enable"

If the output does not match the expected result, this is a finding.

Note: The command must be run from a bash shell and not from a shell generated by the "appliance shell". Use the "chsh" command to change the shell for the account to "/bin/bash". Refer to KB Article 2100508 for more details:

https://kb.vmware.com/s/article/2100508
Fix Text (F-62797r935347_fix)
Navigate to and open:

/opt/vmware/etc/lighttpd/lighttpd.conf

Add or reconfigure the following value:

server.fips-mode = "enable"

Restart the service with the following command:

# vmon-cli --restart applmgmt