Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-256544 | PHTN-30-000074 | SV-256544r887306_rule | Medium |
Description |
---|
Without setting a balance between performance and ensuring all audit events are written to disk, performance of the system may suffer or the risk of missing audit entries may be too high. |
STIG | Date |
---|---|
VMware vSphere 7.0 vCenter Appliance Photon OS Security Technical Implementation Guide | 2023-06-15 |
Check Text ( C-60219r887304_chk ) |
---|
At the command line, run the following command: # grep -E "freq|flush" /etc/audit/auditd.conf Expected result: flush = INCREMENTAL_ASYNC freq = 50 If the output does not match the expected result, this is a finding. |
Fix Text (F-60162r887305_fix) |
---|
Navigate to and open: /etc/audit/auditd.conf Ensure the following line is present and any existing "flush" and "freq" settings are removed: flush = INCREMENTAL_ASYNC freq = 50 |