Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-243085 | VCTR-67-000016 | SV-243085r719498_rule | Medium |
Description |
---|
The distributed virtual switch can export NetFlow information about traffic crossing the switch. NetFlow exports are not encrypted and can contain information about the virtual network, making it easier for a MitM attack to be executed successfully. If NetFlow export is required, verify that all NetFlow target IPs are correct. |
STIG | Date |
---|---|
VMware vSphere 6.7 vCenter Security Technical Implementation Guide | 2021-04-16 |
Check Text ( C-46360r719496_chk ) |
---|
To view NetFlow Collector IPs configured on distributed switches: From the vSphere Client, go to Networking >> select a distributed switch >> Configure >> Settings >> NetFlow. View the NetFlow pane and verify that any collector IP addresses are valid and in use for troubleshooting. or From a PowerCLI command prompt while connected to the vCenter server, run the following command: Get-VDSwitch | select Name,@{N="NetFlowCollectorIPs";E={$_.ExtensionData.config.IpfixConfig.CollectorIpAddress}} To view if NetFlow is enabled on any distributed port groups: From the vSphere Client, go to Networking >> select a distributed port group >> Manage >> Settings >> Policies. Go to Monitoring and view the NetFlow status. or From a PowerCLI command prompt while connected to the vCenter server, run the following command: Get-VDPortgroup | select Name,VirtualSwitch,@{N="NetFlowEnabled";E={$_.Extensiondata.Config.defaultPortConfig.ipfixEnabled.Value}} If NetFlow is configured and the collector IP is not known and documented, this is a finding. |
Fix Text (F-46317r719497_fix) |
---|
To remove collector IPs: From the vSphere Client, go to Networking >> select a distributed switch >> Configure >> Settings >> NetFlow. Click "Edit" and remove any unknown collector IPs. or From a PowerCLI command prompt while connected to the vCenter server, run the following commands: $dvs = Get-VDSwitch dvswitch | Get-View ForEach($vs in $dvs){ $spec = New-Object VMware.Vim.VMwareDVSConfigSpec $spec.configversion = $vs.Config.ConfigVersion $spec.IpfixConfig = New-Object VMware.Vim.VMwareIpfixConfig $spec.IpfixConfig.CollectorIpAddress = "" $spec.IpfixConfig.CollectorPort = "0" $spec.IpfixConfig.ActiveFlowTimeout = "60" $spec.IpfixConfig.IdleFlowTimeout = "15" $spec.IpfixConfig.SamplingRate = "0" $spec.IpfixConfig.InternalFlowsOnly = $False $vs.ReconfigureDvs_Task($spec) } Note: This will reset the NetFlow collector configuration back to the defaults. To disable NetFlow on a distributed port group: From the vSphere Client, go to Networking >> select a distributed port group >> Manage >> Settings >> Policies. Go to "Monitoring" and change "NetFlow" to disabled. or From a PowerCLI command prompt while connected to the vCenter server, run the following commands: $pgs = Get-VDPortgroup | Get-View ForEach($pg in $pgs){ $spec = New-Object VMware.Vim.DVPortgroupConfigSpec $spec.configversion = $pg.Config.ConfigVersion $spec.defaultPortConfig = New-Object VMware.Vim.VMwareDVSPortSetting $spec.defaultPortConfig.ipfixEnabled = New-Object VMware.Vim.BoolPolicy $spec.defaultPortConfig.ipfixEnabled.inherited = $false $spec.defaultPortConfig.ipfixEnabled.value = $false $pg.ReconfigureDVPortgroup_Task($spec) } |